OPS.1.1.5 Protokollierung: How to Implement the BSI Logging Requirements
24.11.2026
The BSI logging module OPS.1.1.5 Protokollierung is implemented in three stages, following the levels of its requirements. First, the Basis requirements A1, A3, A4 and A5 must be met: a logging policy, the logging of all security-relevant events, time synchronisation and compliance with the legal framework. Second, the Standard requirements A6, A8, A9 and A10 should be met: a central logging infrastructure, archiving, the provision of log data for evaluation and the protection of log data against change and deletion. Third, at elevated protection needs, the organisation decides on A11 to A13 in an individual risk analysis. BSI stands for the Bundesamt für Sicherheit in der Informationstechnik, the German Federal Office for Information Security. Edition 2023 of the IT-Grundschutz-Kompendium remains the latest edition, and the BSI published Grundschutz++, the further development of IT-Grundschutz, as BSI-Standard 300-1 on 26 October 2026.
What is the BSI module OPS.1.1.5 Protokollierung?
OPS.1.1.5 Protokollierung is a module of the BSI IT-Grundschutz-Kompendium that defines the cross-cutting requirements for logging security-relevant events in an Informationsverbund (the defined scope of IT systems, applications and processes).
The goal of the module is to collect all relevant data securely, to store it and to provide it in a form suitable for evaluation. The module is applied once to the whole Informationsverbund. It covers only cross-cutting aspects. Logging of specific IT systems and applications is described in their own modules. The protection of the underlying operating system is covered by operating-system modules, for example SYS.1.2.3 Windows Server.
The module assigns responsibility to IT-Betrieb (IT operations) as the basic responsible role. Fachverantwortliche (the business owners of systems and applications) are named as further responsible roles. The general method behind the modules is explained in What is BSI IT-Grundschutz and how is it implemented step by step?
Who has to implement OPS.1.1.5?
The module binds organisations that are obliged to apply the IT-Grundschutz-Kompendium and serves as a reference for all others. Federal administration bodies (Einrichtungen der Bundesverwaltung) must meet the minimum requirements from BSI-Standards, the IT-Grundschutz-Kompendium and Mindeststandards under § 44 Abs. 1 of the BSI-Gesetz (BSIG).
Other organisations apply the module when they have adopted IT-Grundschutz, when a contract requires it or when they hold a certification of the type “ISO 27001 auf Basis von IT-Grundschutz”. For private companies without such a duty, IT-Grundschutz is voluntary. The module then serves as a reference for the Stand der Technik (state of the art) in logging.
Is OPS.1.1.5 still valid with Grundschutz++?
Yes. OPS.1.1.5 is part of Edition 2023 of the IT-Grundschutz-Kompendium, and Edition 2023 is the latest edition. The BSI published Grundschutz++ as BSI-Standard 300-1 on 26 October 2026. The BSI describes it as a further development of IT-Grundschutz with a process-oriented approach and a focus on core business processes.
The BSI Meilensteinplan (milestone plan, status October 2026) contains the following dates:
- A Grundschutz++ ISMS (Informationssicherheits-Managementsystem, information security management system) is certifiable from 1 January 2027 and is compatible with ISO/IEC 27001.
- The early-adopter phase is planned from Q1 2027 to 31 December 2027.
- Certification under IT-Grundschutz remains possible until 30 November 2031.
According to the BSI, the Stand der Technik Bibliothek (the library of state-of-the-art requirements) replaces the IT-Grundschutz-Kompendium. The Anwenderkatalog (the catalogue of requirements for users) is part of this library, and its requirements are available in machine-readable form.
Until a migration, OPS.1.1.5 remains the reference for organisations that work with IT-Grundschutz. Before a migration, the existing logging measures can be reviewed against the requirements of the Anwenderkatalog.
Which requirements does OPS.1.1.5 contain?
OPS.1.1.5 contains eleven active requirements, A1 to A13 without A2 and A7, which the BSI has removed. The table lists each requirement with its German title, its level (B = Basis, S = Standard, H = elevated protection needs) and its core content.
| ID | Title | Level | Core content |
|---|---|---|---|
| A1 | Erstellung einer Sicherheitsrichtlinie für die Protokollierung | B | Logging policy derived from the general security policy |
| A2 | ENTFALLEN | B | Removed |
| A3 | Konfiguration der Protokollierung auf System- und Netzebene | B | All security-relevant events logged, existing logging functions used |
| A4 | Zeitsynchronisation der IT-Systeme | B | Synchronous system time, uniform date and time format |
| A5 | Einhaltung rechtlicher Rahmenbedingungen | B | Data protection, co-determination, controlled deletion |
| A6 | Aufbau einer zentralen Protokollierungsinfrastruktur | S | Central storage in a dedicated network segment |
| A7 | ENTFALLEN | S | Removed |
| A8 | Archivierung von Protokollierungsdaten | S | Archiving under statutory rules |
| A9 | Bereitstellung von Protokollierungsdaten für die Auswertung | S | Filtered, normalised, aggregated and correlated data for evaluation |
| A10 | Zugriffsschutz für Protokollierungsdaten | S | Administrators cannot change or delete log data |
| A11 | Steigerung des Protokollierungsumfangs | H | More events, shorter storage intervals, whole Informationsverbund |
| A12 | Verschlüsselung der Protokollierungsdaten | H | Encryption in transit, signatures, encrypted archives |
| A13 | Hochverfügbare Protokollierungsinfrastruktur | H | Highly available logging infrastructure |
The BSI uses fixed modal verbs. Basis requirements MÜSSEN vorrangig erfüllt werden (must be met first). Standard requirements together with Basis requirements correspond to the Stand der Technik, and Standard requirements SOLLTEN grundsätzlich erfüllt werden (should be met as a rule). The H requirements are exemplary proposals. They SOLLTEN bei erhöhtem Schutzbedarf in Betracht gezogen werden (should be considered at elevated protection needs), and the organisation decides on them in an individual risk analysis. A SOLLTE requirement is not optional: a deviation needs a justification that an auditor can check.
How do you meet the basis requirements of OPS.1.1.5?
The basis requirements A1, A3, A4 and A5 must be met first. They define the policy, the scope of logging, time synchronisation and the legal framework. Each section separates the BSI requirement from a practical implementation.
What belongs in a logging security policy (A1)?
A logging security policy (Sicherheitsrichtlinie für die Protokollierung) must state how logging is planned, built and operated, and how, where and what is logged. The policy is derived from the general security policy of the organisation. The module also calls it the Protokollierungsrichtlinie (logging policy).
The type and scope of logging should follow the protection needs of the information. The following rules apply to its creation and use:
- The ISB (Informationssicherheitsbeauftragter, information security officer) creates the policy together with the Fachverantwortliche.
- The policy must be known to all staff responsible for logging.
- Changes and deviations must be agreed with the ISB and documented.
- The implementation must be checked regularly, and the results must be documented.
Practical implementation: a versioned document with an owner, an approval and a review date. Typical evidence: the review record of the regular check.
Which events must be logged (A3)?
All security-relevant events of IT systems and applications must be logged. A3 requires the use of the existing logging functions of the relevant systems and compliance with manufacturer guidance. Where a system cannot log, additional systems, for example at network level, must be integrated.
The BSI text does not list events. Typical examples, not BSI wording, are logins and failed logins, changes to privileged accounts and rights, configuration changes, starts and stops of security services and access to sensitive data. The logging policy from A1 fixes the final list.
The module requires spot checks at intervals defined in the policy. Practical implementation: a comparison of the list of logging sources with the systems of the Informationsverbund and a test of whether a defined test event appears in the log. Typical evidence: the check records.
Why does time synchronisation matter (A4)?
Time synchronisation is required because events from different systems can only be correlated and used as evidence when their timestamps are comparable. A4 requires that the system time of all logging systems is synchronous and that log files use a uniform date and time format.
Practical implementation: a central time source distributed by a protocol such as NTP (Network Time Protocol). The configuration of all logging systems then points to the same sources, and the log format uses one notation for date, time and time zone. The ISO counterpart is control 8.17 “Clock synchronization” in Annex A of ISO/IEC 27001:2022.
Which legal rules apply to logging (A5)?
A5 requires compliance with federal and state data protection law, with personality rights and co-determination rights of employee representatives and with all other relevant legal provisions. The requirement contains four elements. The legal references in points 1 and 2 are the author’s additions, not BSI wording.
- Data protection. Logs often contain personal data such as user names and IP addresses. For a private company, the EU General Data Protection Regulation (Datenschutz-Grundverordnung, DSGVO) applies, supplemented by the Bundesdatenschutzgesetz (BDSG). The data protection laws of the federal states (Landesdatenschutzgesetze) bind public bodies of the Länder. Since the judgment of the Court of Justice of the European Union in case C-34/21 (30 March 2023), § 26 BDSG is a doubtful stand-alone legal basis for employee data. In practice, security logging is based on Art. 6(1)(c) or (f) DSGVO in conjunction with Art. 32 DSGVO, or on a Betriebsvereinbarung (works agreement). Art. 5(1)(e) DSGVO permits storage in a form that identifies data subjects for no longer than necessary for the purpose. The DSGVO sets no fixed number of days for log retention. The module refers to CON.2 Datenschutz for personal data.
- Co-determination. § 87 Abs. 1 Nr. 6 BetrVG (Betriebsverfassungsgesetz) gives the works council a right of co-determination on the introduction and use of technical devices that are “dazu bestimmt” (designed) to monitor the behaviour or performance of employees. According to the established case law of the Bundesarbeitsgericht (BAG, Federal Labour Court), it is enough that a device is objectively capable of such monitoring. The employer’s intention does not matter. In practice, almost every form of logging is therefore subject to co-determination where a works council exists. A Betriebsvereinbarung regulates the scope and use. In the public sector, comparable participation rights of staff councils (Personalrat) apply under personnel representation law.
- Deletion. Log data must be deleted according to a defined process.
- Integrity. Uncontrolled deletion or modification must be technically prevented.
Practical implementation: a deletion concept that names the purpose, the retention period and the deletion process for each log type. Typical evidence: the concept and, where applicable, the works agreement.
How do you meet the standard requirements of OPS.1.1.5?
The standard requirements A6, A8, A9 and A10 should be met as a rule. Together with the basic requirements, they correspond to the Stand der Technik. They describe the central infrastructure, the archive, the provision for evaluation, and the access protection.
What does a central logging infrastructure need (A6)?
According to A6, security-relevant log data should be stored centrally in an infrastructure that is placed in a dedicated network segment, dimensioned sufficiently and supported by sufficient resources. The BSI calls the central logging infrastructure a Logserver-Verbund (a group of log servers). The segment is described with reference to NET.1.1.
The following requirements apply to the infrastructure:
- General operational events that indicate errors should also be stored.
- The infrastructure should be dimensioned sufficiently, and scalability should be considered.
- Enough technical, financial, and personnel resources should be available.
Typical evidence: a network plan that shows the segment and a sizing calculation that covers data volume and growth.
How should log data be archived and provided for evaluation (A8, A9)?
Log data should be archived in accordance with statutory rules (A8) and should be provided for evaluation in a prepared form (A9). The module does not set a retention period. The archive concept follows the legal basis and the deletion process from A5.
A9 sets out the following preparation steps and conditions:
- Log data should be filtered, normalised, aggregated, and correlated and made available for evaluation.
- Interfaces for automated evaluation should exist.
- The evaluation should observe the security requirements of the logging policy and consider operational and internal agreements.
- Log data should additionally be kept in its unchanged original form.
Typical evidence: an archive concept with the statutory basis and a description of the preparation steps and interfaces. One example of a log management design is the SecureVisio architecture, which separates the log management layer from correlation and keeps raw and normalised logs in files protected with a hash function and a digital certificate. The design is described in The SecureVisio architecture: scalable data lake, NG-SIEM and high availability by design.
Who may access log data (A10)?
Administrators should have no permission to change or delete the recorded log data. A10 is the access protection requirement of the module. In practice, it concerns the administrators of the logged systems and of the logging infrastructure.
Practical implementation: a role and permission model with read-only access for administrators and a separate role for the operation of the log infrastructure. The module ORP.1 covers roles and separation of duties. Typical evidence: the role and permission matrix.
What applies at elevated protection needs (A11 to A13)?
At elevated protection needs, the requirements A11 to A13 should be considered. They are exemplary proposals, and the organisation decides on them in an individual risk analysis.
- A11 Steigerung des Protokollierungsumfangs. More events should be logged so that security incidents are traceable as completely as possible. Central storage intervals should be shorter to allow real-time evaluation. The evaluation should cover the whole Informationsverbund. Applications and systems that cannot log centrally should not be used (SOLLTEN NICHT eingesetzt werden) at elevated protection needs.
- A12 Verschlüsselung der Protokollierungsdaten. Log data should be encrypted in transit. All stored logs should be digitally signed. Archived logs and logs stored outside the infrastructure should always be stored encrypted.
- A13 Hochverfügbare Protokollierungsinfrastruktur. A highly available logging infrastructure should be built.
Typical evidence: the risk analysis that justifies the decision, the encryption and signature configuration and the design of the high availability.
Where does OPS.1.1.5 end and DER.1 begin?
OPS.1.1.5 ends where the evaluation of log data begins. The module covers collecting, storing and preparing log data, and A9 includes filtering, normalisation, aggregation and correlation as preparation for evaluation. The evaluation itself (Auswertung) and the detection of security-relevant events belong to DER.1. The module names its boundaries as follows:
- DER.1 covers the detection of security-relevant events and the evaluation of log data.
- DER.2.1 covers incident handling.
- OPS.1.2.2 Archivierung covers long-term, secure, unchangeable and reproducible storage. A8 in OPS.1.1.5 only requires that log data is archived.
- CON.2 Datenschutz covers personal data.
- ORP.1 covers roles and separation of duties.
- System-specific modules cover the logging of single systems, and operating-system modules such as SYS.1.2.3 Windows Server protect the underlying operating system.
A SIEM (Security Information and Event Management system) is a typical tool for DER.1 evaluation. It uses the log data from OPS.1.1.5 as input. The details are explained in What is SIEM (Security Information and Event Management)?
How does OPS.1.1.5 relate to NIS2, KRITIS and ISO 27001?
OPS.1.1.5 relates to NIS2, KRITIS and ISO 27001 as a reference for the Stand der Technik in logging, and no law names the module. NIS2 is the EU directive on network and information security. KRITIS is the common short form for kritische Infrastrukturen (critical infrastructures). The new BSIG uses the term kritische Anlagen (critical facilities) for the regulated facilities. The German implementation of NIS2 is the new BSIG, in force since 6 December 2025.
- § 30 BSIG. Besonders wichtige und wichtige Einrichtungen (particularly important and important entities) must take appropriate, proportionate and effective measures (§ 30 Abs. 1 BSIG). These measures should comply with the Stand der Technik and take relevant European and international standards into account, and they must follow an all-hazards approach (§ 30 Abs. 2 BSIG). The minimum measures include the handling of security incidents (Nr. 2). The entity must document compliance (§ 30 Abs. 1 BSIG). Logging provides the data for incident handling and for documentation. For the legal background, see What is the NIS2 Directive and what do companies need to know by 2026?
- § 31 Abs. 2 BSIG. Betreiber kritischer Anlagen (operators of critical facilities) must deploy Systeme zur Angriffserkennung (attack detection systems) for the IT systems, components and processes that are relevant to the functioning of their critical facilities. These systems must “kontinuierlich und automatisch erfassen und auswerten”. Logging per OPS.1.1.5 supplies the data. The evaluation is the task of DER.1 and of the attack detection system.
- § 44 BSIG. Federal administration bodies must meet the Mindeststandards. The module lists the BSI Mindeststandard zur Protokollierung und Detektion von Cyber-Angriffen as further information.
- ISO/IEC 27001:2022. The former control group A.12.4 (logging and monitoring) corresponds mainly to Annex A controls 8.15 “Logging” and 8.17 “Clock synchronization”. Control 8.16 “Monitoring activities” is new in the 2022 edition. It covers monitoring rather than logging and therefore corresponds more closely to DER.1 than to OPS.1.1.5.
- NIST SP 800-92. The module lists “Guide to Computer Security Log Management” as an international reference. The guide dates from 2006. NIST has published a draft revision, SP 800-92 Rev. 1 “Cybersecurity Log Management Planning Guide”.
Which evidence do auditors expect for OPS.1.1.5?
Auditors expect documents and records that show how each requirement is met. The module does not define evidence, so the checklist below is a practical suggestion, not BSI wording.
- A1: approved logging policy with version number and review record.
- A3: list of logging sources compared with the policy, and records of the spot checks.
- A4: time synchronisation configuration of the logging systems and the log format definition.
- A5: deletion concept and, where applicable, the Betriebsvereinbarung.
- A6: network plan of the log segment and sizing calculation of the log infrastructure.
- A8: archive concept with the statutory basis.
- A9: description of filtering, normalisation, correlation and interfaces, and proof of the stored original form.
- A10: role and permission matrix that shows that administrators cannot change or delete log data.
- A11 to A13 (elevated protection needs): risk analysis, encryption and signature configuration, and the high availability design.
Frequently asked questions
No. IT-Grundschutz is voluntary for private companies, unless the company has adopted it, holds a certification based on it or is bound by contract. Federal administration bodies are bound by § 44 BSIG. Private companies that fall under NIS2 must meet § 30 BSIG, and the module serves them as a reference for the Stand der Technik.
The module sets no storage period. OPS.1.1.5 requires archiving under statutory rules (A8) and a defined deletion process (A5). The period is set per log type in the retention concept, based on the purpose and the legal basis. The DSGVO sets no fixed number of days.
No. OPS.1.1.5 sets central logging (A6) and the preparation of log data for evaluation (A9) as Standard requirements (SOLLTE). The evaluation itself is the subject of DER.1. No law names a SIEM. For operators of critical facilities, § 31 Abs. 2 BSIG requires attack detection systems, and a SIEM is a typical tool for this evaluation.
Yes, where a works council exists and logging can monitor the behaviour or performance of employees. § 87 Abs. 1 Nr. 6 BetrVG gives the works council a right of co-determination in this case. The usual form of agreement is a Betriebsvereinbarung.
OPS.1.1.5 Protokollierung defines the logging requirements for the whole Informationsverbund in eleven active requirements. The basis requirements A1, A3, A4 and A5 must be met first. They cover the policy, the events, time synchronisation and the legal framework. The standard requirements A6, A8, A9 and A10 should be met as a rule and cover the central infrastructure, archiving, provision for evaluation and access protection. The requirements A11 to A13 should be considered at elevated protection needs. Edition 2023 of the Kompendium is the latest edition, Grundschutz++ is certifiable from 1 January 2027, and certification under IT-Grundschutz remains possible until 30 November 2031. The evidence for an audit is a set of documents and records per requirement.
Table of contents